3, each house into the family line section should not be less than 10 mm,
so for ordinary families, 1.5 square mm line with lamps, switch, socket,
grounding wire with 2.5 mm can, and the installation of air-conditioning,
electrical power lines should be separate go up 4 square mm line. For the entire
line, the number of branch circuit should not be too small, generally should be
light to go all the way, air conditioning to take the two road, the outlet to go
three to four. The advantage of this is that once a short circuit or other
problems occur, the scope of the power outage is small, will not affect the
normal work of other roads.
4, the same room of the switch or socket height should be consistent, the
general switch from the ground 1.4 meters, away from the door frame 15~20cm. The
socket is suitable for 30cm. Air conditioner socket from the ground 2 meters
above the ground 30cm socket cabinet. The kitchen socket is 1 meters (cabinet
height of about 80cm). The socket on the table: such as bedside cabinets,
dresser, kitchen, the bottom of the socket should be from table 10cm. A double
control switch about 85CM height; height according to the size of the space
power hanging TV and TV size determine the general height of 1000-1200MM.
5, in the routing process, should follow the "line into switches, zero line
into cap" principle; socket wiring to be "left zero right N fire L, PE on the
ground" or "lit under zero".
In order to prevent children from getting an electric shock, with the touch
of a finger or metal plug power supply must be chosen to poke holes, safety
socket with baffle insurance. In addition, the need for regular switching power
supply, consider the use of a socket with a switch.
6, the living room lighting should be respectively in the door and bedroom
door installed double control switch (to go to sleep when the lights go directly
back to the bedroom to sleep, not to find the dark bedroom door this evening).
Similarly, the bedroom lighting should be installed in the bedroom door and
bedside dual control switch. In addition, suggestions to install wall lamp lamp
bedside lamp instead of (saving space).
8, electric power required for the bomb line slot, laid separately (the
spacing between electricity to 30-50 cm), and cold bending pipe threading (cold
bending pipe with bending tool, radian should be 10 times the diameter of the
pipe line, this line can wear or stitches, smooth).
9、水電的施工原則就是,走頂不走地,頂不能走,考慮走墻,墻也不能走,才考慮走地。
9, water and electricity construction principle is, go to the top of the
ground, the top can not go, consider the wall, the wall can not go, just
consider the ground.
走頂的線(xiàn)在吊頂或者石膏線(xiàn)里面,檢修方便。
The top of the line in the ceiling or gypsum line inside, convenient
maintenance.
走墻怕傷害到混凝土層,甚至鋼筋,并且避免大面積橫向開(kāi)槽,怕影響墻的承重力。
The wall is afraid of damage to the concrete floor, and even steel, and
avoid a large area of transverse slot, afraid of the impact of the wall bearing
capacity.
走地的,在檢修時(shí)就要將地板掀起來(lái)。
Go, in the maintenance of the floor will be lifted up.
Therefore, a large area of walking, walk or go to the top should be
considered, if the top surface has a ceiling, can give priority to, otherwise
considered on the ground (toilet, kitchen etc. to take the top).
二、水路改造裝修:
Two, water renovation and decoration:
1、水管盡可能走墻。
1, water pipes as far as possible to the wall.
2、水管用PPR管,管線(xiàn)為紅色為熱水管,管線(xiàn)為籃色為冷水管。
2, the water pipe with PPR pipe, the pipeline for the red hot water pipe,
the pipe line for the basket of cold water pipe.
3, specifications: PPR water pipe can be divided into 20mm according to the
size, 25mm and 32mm, of which 20mm is relatively small, commonly known as the 4
charge, 25mm is in charge of 6 (commonly known as home improvement suggestions
are 6 in charge of water), 32mm is generally into the household work; in
accordance with the wall thickness, can be divided into 2.8mm and 4.2mm, 2.8 is
a cold water pipe, hot water pipe is 4.2, we are using 4.2mm thick.
4, hot and cold water pipes should be left hot right cold, cold hot water
joint spacing of 15cm, distance to the ground 1-1.200m. Flip on the washing
machine gate height 1.2M. The basin, the basin to the nozzle height of
45-55cm.
These are small as hydropower transformation share Beijing office
decoration company notice, if we do not pay attention to the water and
electricity once the decoration problems, will give the follow-up decoration and
home life bring great trouble. Renovation of water and electricity to pay
attention to what are the friends of the decoration of small series for you to
answer this question today.